Design and access statement
Note:
From 25 June 2013, design and access statements are only required for buildings of more than 1,000 sq. m, housing developments of 10 dwellings or more and developments requiring listed building consent. In conservation areas, design and access statements are required for single dwellings or buildings of more than 100 sq. m.
Requirements for design and access statements must also be proportionate to the scale of the proposed development, and any information requests must be necessary to validate the application. Applicants are allowed to challenge demands that they think are unnecessary and local authorities then either have to justify the demand or waive it.
For more information see The Town and Country Planning (Development Management Procedure) (England) (Amendment) Order 2013.
Design and access statements are prepared as part of the documentation to support a planning application. They explain the design principles and concepts that have been applied to particular aspects of the proposed development. Design and access statements may include plans, elevations and other illustrations, photographs and for large or complex schemes a model of the proposed development.
Design and access statements should explain:
- Amount (how much development is proposed). For residential development, this the number of proposed units and for all other development, the proposed floor space for each proposed use.
- Layout:
- The relationship between buildings and public and private spaces within and around the site.
- Accessibility of the site for users, such as travel distances and gradients, and the orientation of blocks and units in relation to any site topography to afford optimum accessibility.
- The impact of the layout on the energy consumption and thermal comfort during winter and summer performance.
- Crime prevention measures.
- Scale:
- The height, width and length of a building or buildings in relation to its surroundings.
- The size of building parts, particularly entrances and facades.
- Why particular heights have been selected.
- How these relate to the site’s surroundings and skyline.
- How they relate to the human scale.
- Purpose of landscaping private and public spaces.
- Its relationship to the surrounding area.
- A schedule of planting and landscaping materials.
- Appearance of the development:
- The appearance of the place or buildings proposed.
- How this relates to the appearance and character of the development’s surroundings.
- How the decisions about texture, contrast, tone and lighting have considered accessibility.
- Context:
- Steps taken to understand the local context (physical, social and economic characteristics as well as planning policies).
- How local context has influenced the design.
- Consultation with the local community and local access groups as well as with local authority planning, building control, conservation and design and access officers. Explanation of how these views have been take into account.
- Opportunities, constraints and conflicting issues.
- Use:
- Proposed use or uses.
- Their distribution across the site.
- Accessibility to and between them.
- Their relationship to uses surrounding the site.
- Access (access to the development, not internal aspects of buildings):
- Access to buildings, spaces and transport.
- Flexibility and responsiveness to changing needs.
- Any consultation undertaken.
- Access for emergency services if appropriate.
NB: The National Planning Policy Framework makes clear that there should be a presumption in favour of sustainable developments. This should be reflected in design and access statements.
[edit] Related articles on Designing Buildings
- Building regulations.
- Constraints.
- Detailed planning application.
- Outline planning application.
- National Planning Policy Framework.
- Planning permission.
- Statutory approvals.
- Sustainability.
[edit] External references
Featured articles and news
Ebenezer Howard: inventor of the garden city. Book review.
The Grenfell Tower fire, eight years on
A time to pause and reflect as Dubai tower block fire reported just before anniversary.
Airtightness Topic Guide BSRIA TG 27/2025
Explaining the basics of airtightness, what it is, why it's important, when it's required and how it's carried out.
Construction contract awards hit lowest point of 2025
Plummeting for second consecutive month, intensifying concerns for housing and infrastructure goals.
Understanding Mental Health in the Built Environment 2025
Examining the state of mental health in construction, shedding light on levels of stress, anxiety and depression.
The benefits of engaging with insulation manufacturers
When considering ground floor constructions.
Lighting Industry endorses Blueprint for Electrification
The Lighting Industry Association fully supports the ECA Blueprint as a timely, urgent call to action.
BSRIA Sentinel Clerk of Works Training Case Study
Strengthening expertise to enhance service delivery with integrated cutting-edge industry knowledge.
Impact report from the Supply Chain Sustainability School
Free sustainability skills, training and support delivered to thousands of UK companies to help cut carbon.
The Building Safety Forum at the Installershow 2025
With speakers confirmed for 24 June as part of Building Safety Week.
The UK’s largest air pollution campaign.
Future Homes Standard, now includes solar, but what else?
Will the new standard, due to in the Autumn, go far enough in terms of performance ?
BSRIA Briefing: Cleaner Air, Better tomorrow
A look back at issues relating to inside and outside air quality, discussed during the BSRIA briefing in 2023.
Restoring Abbotsford's hothouse
Bringing the writer Walter Scott's garden to life.
Reflections on the spending review with CIAT.
Retired firefighter cycles world to raise Grenfell funds
Leaving on 14 June 2025 Stephen will raise money for youth and schools through the Grenfell Foundation.
Key points for construction at a glance with industry reactions.
Comments
http://www.legislation.gov.uk/uksi/2013/1238/article/4/made
This says 'the provision of a building or buildings where the floor space created by the development is 100 square metres or more.' Not 1000sqm.
Is this an error?
That is only in designated areas - ie conservation areas.